Adding a branch to a corrugated conduit run with a closed Y-fitting means feeding the wires through the fitting from the conduit end, so an existing harness has to come apart first. The GYTF opens up instead: snap the conduit into the matching ports, close the body, and lock it with the clip. Nothing is threaded on from the end, and one conduit run splits into a main line and a branch.
The body is injection molded from PA66 nylon with a UL 94 V-2 flame rating. It is non-metallic and won't rust, and the thick-walled body with its clip lock stands up to pulling and long-term use. Equal and reducing sizes fit conduit OD from 10 mm to 34.5 mm (AD10 to AD34.5). Select by the conduit size of the main run and the branch.
| Specification | Value |
|---|---|
| Material | PA66 nylon |
| Flame Rating | UL 94 V-2 |
| Structure | Split body with clip lock |
| Installation | Snap-fit |
| Conduit OD | 10–34.5 mm (AD10–AD34.5) |
| Color | Black |
Note: AD is the corrugated conduit OD code in millimeters (for example, AD21.2 = 21.2 mm OD). Port sizes A, B, and C, plus the length and height of each size, are listed in the product data table below.
A, B, and C are the conduit ODs that fit each of the three ports. LENGTH is the overall length; ALTITUDE (overall height) is the overall height of the fitting.
Split one conduit run into a main line and a branch. Choose an equal size when both conduits share the same OD and a reducing size when they differ, then check ports A, B, and C in the data table.
The split body snaps onto the conduit without feeding it on from the end, which makes adding or rerouting a branch in the field easier.
Equal and reducing combinations cover conduit OD from 10 mm to 34.5 mm, so fittings can be matched to the size of each harness.
The GYTF fits corrugated conduit OD from 10 mm to 34.5 mm (AD10 to AD34.5). Equal sizes are available in 10, 13, 15.8, 18.5, 21.2, 25, and 28.5 mm (AD10 through AD28.5), plus reducing combinations. For the A, B, and C port sizes of each model, see the product data table on this page, or email your requirements and the sales team will help select the right size.
If the main run and the branch use conduit with the same OD, choose an equal size. If the ODs differ, choose a reducing size. To select, match the conduit OD (AD) to columns A, B, and C in the data table.
Open the body, snap the conduit into the matching ports, then close the body and lock the clip. The conduit does not need to be fed in from the end. After installation, check that the clip is fully engaged and the conduit sits tight in each port.
The GYTF is made of PA66 nylon with a UL 94 V-2 flame rating, and the non-metallic body won't rust. No IP rating is specified for the GYTF. For applications that need a waterproof fitting, see the Waterproof Y-Type Corrugated Tube Fitting GY-AD.
Yes, samples are available on request. Fill out the contact form or click Send Inquiry Email above, and include your conduit size combination and application. For size combinations not listed, email the sales team with your requirements to request a quote.
| {{ typeOne.merge }} |
|---|
| {{ itemOneTitle }} |
| {{ item }} |
| {{ typeTwo.merge }} |
|---|
| {{ itemTwoTitle }} |
| {{ item }} |
| {{ typeThree.merge }} |
|---|
| {{ itemThreeTitle }} |
| {{ item }} |